![]() Users should refer to the original published version of the material for the full abstract. No warranty is given about the accuracy of the copy. However, users may print, download, or email articles for individual use. Copyright of Annals of Laboratory Medicine is the property of Korean Society for Laboratory Medicine and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission.Abbotts i-STAT 1 POC blood analyzer, for example, can run multiple tests. i-SmartCare 10 shows acceptable performance, and using a single POC blood gas analyzer is recommended for monitoring. Author: Kimberly Scott // Date: MAY.1.2020 // Source: Clinical Laboratory News. Blood Chemistry section for a description of this technology). Forty of 48 items demonstrated either a proportional or systematic difference in regression analysis the relative mean difference (%) of 14/48 items escaped the allowable total error in the difference plot analysis. electrochemical detection in the i-STAT design (see. Interference was noted for Na+ in the presence of a high K+ level and for iCa2+ in the presence of high K+ and Mg2+ levels. POCT is near-patient testing that is performed near or at the site of a patient, with the result leading to possible change in the care of the patient (). The total imprecision and linearity (r2>0.99) were excellent, except for a few analytes that narrowly escaped the preset criteria. Point-of-care testing (POCT) is a rapidly expanding area of laboratory medicine. Na+ and K+ done via POCT using i-STAT compared well with results by the. Ten analytes (pH, pCO2, pO2, Na+, K+, Cl-, iCa2+, glucose, lactate, and Hct) were tested on six analyzers: i-SmartCare 10, ABL90 FLEX PLUS (Radiometer Medical ApS, Copenhagen, Denmark), i-Stat (Abbott Point of Care Inc., Princeton, NJ, USA), RapidLab 1265 (Siemens Healthcare Diagnostics Inc., Tarrytown, NY, USA), Stat Profile pHOx Ultra (Nova Biomedical, Waltham, MA, USA), and Gem Premier 5000 (Instrumentation Laboratory, Bedford, MA, USA). patient years, p 0.63) between patients in the 2 different models (POC based. Can be used as an aid in the diagnosis and treatment of myocardial infarction (MI) i-STAT Crea Cartridge. We evaluated the performance of i-SmartCare 10 (i-SENS Inc., Seoul, Korea) and conducted a method comparison study of five point-of-care (POC) analyzers with i-SmartCare 10 as the comparator, according to the CLSI guidelines. With i-STAT CHEM8+, healthcare professionals can obtain chemistries, electrolytes, hematocrit and hemoglobin levels in approximately two minutes without leaving the patients side. Abstract: Blood gas, electrolyte, glucose, and lactate level measurement have an immediate and critical impact on patient care. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |